DescriptionThe car is fitted with a horn system which consists of two hornswith different tones: a high tone and a low tone horn. Both hornsare activated simultaneously.The horns are operated by pressing the sidesof the steering wheel cover (Air Bag).The horn circuit is protected by a specialfuse and controlled by a specific relay located in the junctionbox.For safety reasons, the horns can be operatedat any time, even when the key is turned to OFF (or removed).
Functional description The horn system is supplied through the horn relay R2 ,located in the junction unit B1 from the direct line throughthe fuse F13 - always for B1 - and the maxifuse J/B1 of B5 up to 2/99 or B99 from 2/99. The coil of the relay R2 is energizedby an earth signal when one of the steering switches is closed;these switches are connected via the clock spring to the stalk unit H5 .The relay thereby supplies the high tone horn P10 and thelow tone horn P11 .
0Removing201Refitting21Place the car on a ramp.Undo the bolt securing the bracket on thebattery mount.Release the battery from the anchoragebracket complete with strap and remove.
5530B14
769768768
5530B18
Follow these precautions.769On batteries with an opticam hydrometer,electrolyte level and battery charge status can be monitored qualitativelyby examining the indicator colour:a light, bright colour indicates low electrolytelevel: top up with distilled water;a dark colour without a green area in thecentre indicates that the electrolyte level is correct but chargeis low: recharge the battery;a dark colour with a green area in themiddle indicates that both electrolyte level and charge status arecorrect: no action is necessary. For more details 3238420See subassembly5530 CURRENT GENERATOR . 768Proceed as follows.Check the battery voltage without loadusing the test device recommended by the Service outlets (e.g. 'MICRO360').Depending on the voltage values measured,which define the state of charge of the battery, proceed as follows: If the voltage without load is less than12.10 V, replace the battery ( 32384295530B10battery - r+r ). If the voltage without load is over 12.10V but less than 12.50 V, recharge the battery ( 32384305530B14battery - recharge ). If the voltage without load is over 12.50V, the battery is efficient.If necessary, top up the electrolyte asfollows.Carefully remove the cap strip.Top up with distilled and deionized water,taking care not to allow electrolyte to splash out.768
5530B22
0Removing201Refitting21Place the car on the liftingbridge.1. Open engine compartment cap and disconnect battery negative terminal.2. Disconnect mass terminal on side member.3. Lift the car and disconnect mass terminal on gearbox.4. Lower the car again and remove battery earth lead.2018767
0Removing201Refitting21Disconnect the battery negative terminal.1. Open the protective cover2. Loosen the nut and disconnect the ABS supply lead3. Loosen the nut and disconnect the starter motor supply lead4. Undo the clip and undo the box retaining bolts.5. Loosen the battery positive terminal nut.2018769
5530B52
0Removing201Refitting213238429-5530B10battery - r+rRelease the air duct hose from the mountingbracket on the drip tray. Remove the relay shield.1. Release the relays from the battery drip tray and remove them.2. Undo the nut fixing the air filter mounting bracket to the batterydrip tray.3. Undo the two fixing nuts (3a) and move the connections/electricalwiring mounting bracket (3b) aside.4. Release the accelerator cable from the fastening on the bracket.2018771
0Removing201Refitting21Place the vehicle on a lift.1. Disconnect horn electrical connections (1a, 1b, 1c, 1d).2. Undo the nut.3. Remove the horn.2018832
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking “Accept All”, you consent to the use of ALL the cookies. However, you may visit "Cookie Settings" to provide a controlled consent.
This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.