DescriptionThe car is equipped with two reversing lightssituated iin the centre of the tail-light unit (on the tail-gate).These are operated whenever reverse is engagedvia a switch on the outside of the gear housing.The reversing light circuit is suppliedwith the ignition key turned to MAR - fully independently of theother lights - by a line protected by a fuse in the junction unit.
Functional description The switch for the reversing lights I20 issupplied when the ignition is switched on (INT) by the line forfuse F1 for the junction unit B1 . When reverse gear is engaged, the switchcloses and sends the supply to the reversing lights in the centrerear light cluster on the left F35 and on the right F36 ,via the junction unit B1 (pin 9 connector D and pins 6 and7 of connector G).
0Removing201Refitting21Open the boot lid and undothe two side bolts fixing the inner trim.2018778
5540A68
0Removing201Refitting211. Open the boot lid and undo the bolts fixing the inner lining.2018781
5540A78
0Removing201Refitting211. Open the boot lid and undo the bolts fixing the inner lining.2018784
5540A80
0Removing201Refitting211. Open the trunk lid panel and unscrew the two clamping screwsof the light fender.2. Unloose the check tongs (2a) and extract the light holder (2b).3. Take the lights off from the light holder.(Bayonet joint)2018787
5540A94
0Removing201Refitting211. Operating from the right side, by a screwdriver, and take thelight off.2. Disconnect the electrical connection.2018788
Rear lights cluster right (moving part on boot lid)
0Removing201Refitting211. Disconnect the electrical connection.2. Turn IU+2019 switch (2a) anticlockwisely of about 60° and extractit.To make the opening easier operate by a wrench on the exagonalsection (2b) of the IU+2019 switch. 2018839
0Removing201Refitting211. Open the boot lid, turn and undo the lower studs securing theupper trim.2. Lower upper trim (2a) and unscrew knob (2b) securing the thirdbrake light.3. Prise out the brake light and remove.4. Prise electrical connection (4a) out of support (4b) and disconnect.Recover the light cluster.2018841
5550D17
0Removing201Refitting213238489-5550D16third stop light - r+r1. Unscrew the bolts and remove the mount from the light.2. Undo the bolts.3. Remove the bulb holder.4. Remove the bulbs (press-fit type)2018843
0Removing201Refitting21Place the car on an auto lift.1. Lift the car and disconnect the electrical connection of thereserving light switch.2. Unscrew and take the reserve light switch off.2018845
Position the vehicle on a flat surface.Check fluid level and top up if necessary.Work with the engine cold.Turn the ignition key to the ON position.Wait for the pump to come on and go off.Immediately after it has gone off, check the level of hydraulicfluid in the hydraulic selection gearbox using the special dipstickin the reservoir cover.If necessary, top up the level using therecommended fluid.Turn the ignition to the OFF position.
0Removing201Refitting213237946-2127C12hydraulic gear selection fluid reservoir - r r . 1. Release the electrical connection for the electro-hydraulic selectionsystem electric pump from the support.2. Release the pipe between the electro-hydraulic selection hydraulicunit and the fluid reservoir from the band on the support.3. Release the pipe between the electric pump and the electro-hydraulicselection hydraulic unit from the band on the support.2017134
2127C12
0Removing201Refitting211. Remove the electro-hydraulic selection gearbox hydraulic circuitfluid reservoir cap.Drain the electro-hydraulic selection gearbox hydrauliccircuit fluid reservoir.2. Loosen the band fixing the electro-hydraulic selection gearboxhydraulic circuit fluid reservoir.3. Disconnect the supply and return pipes from the electro-hydraulicselection gearbox hydraulic circuit fluid reservoir.4. Remove the electro-hydraulic selection gearbox hydraulic circuitfluid reservoir.2017146
2127C18
0Removing201Refitting211. Remove the electro-hydraulic gear selection system hydrauliccircuit fluid reservoir cap.Drain the electro-hydraulic gear selectionsystem hydraulic circuit fluid reservoir.2. Release the electrical connection for the electro-hydraulic gearselection system electric pump from the support.3. Loosen the fixing bands and remove the pipe between the hydrauliccircuit fluid reservoir and the electro-hydraulic gear selectionelectric pump.2017149
2127C20
0Removing201Refitting21Connect the Examiner diagnostic equipment.Keep the brake pedal depressed.Select 'Alf 156 Selespeed' on the Examiner.Select 'Control Unit Test' on the Examinerand select the 'Marelli Selespeed Automatic Transmission'.Press 'Active Diagnosis' on the Examinerand select 'Accumulator depressurizing'.Continue with the procedure on the Examiner.3238429-5530B10battery - r+r3238435-5530B52Battery DRIP TRAY/SUPPORT - R.R.1. Remove the electro-hydraulic gear selection system hydrauliccircuit fluid reservoir cap.Drain the electro-hydraulic gear selectionsystem hydraulic circuit fluid reservoir.2. Release the electrical connection for the electro-hydraulic gearselection system electric pump from the support.2017154
2127C22
0Removing201Refitting21Connect the Examiner diagnostic equipment.Keep the brake pedal depressed.Select 'Alf 156 Selespeed' on the Examiner.Select 'Control Unit Test' on the Examinerand select the 'Marelli Selespeed Automatic Transmission'.Press 'Active Diagnosis' on the Examinerand select 'Accumulator depressurizing'.Continue with the procedure on the Examiner.1. Remove the electro-hydraulic selection gearbox hydraulic circuitfluid reservoir cap.Drain the electro-hydraulic selection gearbox hydrauliccircuit fluid reservoir.2. Release the electrical connection for the electro-hydraulic gearselection system electric pump from the support.2017164
2127C30
0Removing201Refitting21Connect the Examiner diagnostic equipment.Select 'Alf 156 Selespeed' on the Examiner.Select 'Control Unit Test' on the Examinerand select the 'Marelli Selespeed Automatic Transmission'.Press 'Active Diagnosis' on the Examinerand select 'Accumulator depressurizing'.Continue with the procedure on the Examiner.Ensure that the ignition key is in OFFposition, then disconnect the negative battery terminal.3237946-2127C12hydraulic gear selection fluid reservoir - r r . 1. Release the electrical connection for the electro-hydraulic gearselection system electric pump from the support and disconnect it.2. Release the pipe between the electro-hydraulic selection hydraulicunit and the fluid reservoir from the band on the support.3. Release the pipe between the electric pump and the electro-hydraulicselection hydraulic unit from the band on the support.2017170
2127C40
0Removing201Refitting21Place the gear lever in neutral.Connect the Examiner diagnostic equipment.Keep the brake pedal depressed.Select 'Alf 156 Selespeed' on the Examiner.Select 'Control Unit Test' on the Examinerand select 'Marelli Selespeed Automatic Transmission'.Press 'Active Diagnosis' on the Examinerand select 'Accumulator depressurizing'.Continue with the procedure on the Examiner. Proceed with removal 3238429-5530B10battery - r+r . Proceed with removal 3238435-5530B52Battery DRIP TRAY/SUPPORT- R.R. . Remove the electro-hydraulic gear selectionsystem hydraulic circuit fluid reservoir cap and drain the reservoirusing a syringe.767Do not reuse the fluid from thehydraulic gear selector system circuit.1. Disconnect the pipe between the electro-hydraulic gear selectionhydraulic unit and the fluid reservoir, hydraulic unit side.2. Undo the connector (2a) and disconnect the pipe between the electricpump and the electro-hydraulic gear selection hydraulic unit (2b),hydraulic unit side. 767The fluid recovered should notbe reused.2017183
2127C25
0Removing201Refitting21Connect the Examiner diagnostic equipment.Keep the brake pedal depressed.Select 'Alf 156 Selespeed' on the Examiner.Select 'Control Unit Test' on the Examinerand select the 'Marelli Selespeed Automatic Transmission'.Press 'Active Diagnosis' on the Examinerand select 'Accumulator depressurizing'.Continue with the procedure on the Examiner. Proceed with removal 3238429-5530B10battery - r+r . Proceed with removal 3238435-5530B52Battery DRIP TRAY/SUPPORT- R.R. . Proceed with removal 3237525-1048A10air cleaner filtering element- replace . Proceed with removal 3238966-7055B54under-engine guard -r r . 1. Undo the connector and disconnect the pipe between the selectionsolenoid valve and the engagement/selection actuator, hydraulicactuator unit side.2069788
2127C26
0Removing201Refitting21Connect the Examiner diagnostic equipment.Keep the brake pedal depressed.Select 'Alf 156 Selespeed' on the Examiner.Select 'Control Unit Test' on the Examinerand select the 'Marelli Selespeed Automatic Transmission'.Press 'Active Diagnosis' on the Examinerand select 'Accumulator depressurizing'.Continue with the procedure on the Examiner. Proceed with removal 3238429-5530B10battery - r+r . Proceed with removal 3238435-5530B52Battery DRIP TRAY/SUPPORT- R.R. . Proceed with removal 3237525-1048A10air cleaner filtering element- replace . Proceed with removal 3238966-7055B54under-engine guard -r r . 1. Undo the connector and disconnect the pipe between the unevengear engagement solenoid valve and the engagement/selection actuator,hydraulic actuator unit side. 2069792
2127C27
0Removing201Refitting21Connect the Examiner diagnostic equipment.Keep the brake pedal depressed.Select 'Alf 156 Selespeed' on the Examiner.Select 'Control Unit Test' on the Examinerand select the 'Marelli Selespeed Automatic Transmission'.Press 'Active Diagnosis' on the Examinerand select 'Accumulator depressurizing'.Continue with the procedure on the Examiner. Proceed with removal 3238429-5530B10battery - r+r . Proceed with removal 3238435-5530B52Battery DRIP TRAY/SUPPORT- R.R. . Proceed with removal 3237525-1048A10air cleaner filtering element- replace . Proceed with removal 3238966-7055B54under-engine guard -r r . 1. Undo the connector and disconnect the pipe between the even gearengagement solenoid valve and the engagement/selection actuator,hydraulic actuator unit side.2069796
2127C28
0Removing201Refitting21Connect the Examiner diagnostic equipment.Select 'Alf 156 Selespeed' on the Examiner.Select 'Control Unit Test' on the Examinerand select the 'Marelli Selespeed Automatic Transmission'.Press 'Active Diagnosis' on the Examinerand select 'Accumulator depressurizing'.Continue with the procedure on the Examiner. Proceed with removal 3238429-5530B10battery - r+r . Proceed with removal 3238435-5530B52Battery DRIP TRAY/SUPPORT- R.R. . Proceed with removal 3237525-1048A10air cleaner filtering element- replace . 1. Undo the connector and disconnect the pipe between the clutchengagement solenoid valve and the clutch hydraulic actuator, hydraulicactuator unit side.2069800
2127C44
0Removing201Refitting21Position the vehicle on the rampConnect the Examiner diagnostic equipment.Select 'Alf 156 Selespeed' on the Examiner.Select 'Control Unit Test' on the Examinerand select the 'Marelli Selespeed Automatic Transmission'.Press 'Active Diagnosis' on the Examinerand select 'Accumulator depressurizing'.Continue with the procedure on the Examiner. Proceed with removal 3238429-5530B10battery - r+r . Proceed with removal 3238435-5530B52Battery DRIP TRAY/SUPPORT- R.R. . 1. Undo the upper bolt fixing the pressure accumulator collar tothe gearbox.2069818
0Removing201Refitting21Place the gear lever in neutral, N.Connect the Examiner diagnostic equipment.Select 'Alf 156 Selespeed' on the Examiner.Select 'Control Unit Test' on the Examinerand select the 'Marelli Selespeed Automatic Transmission'.Press 'Active Diagnosis' on the Examinerand select 'Accumulator depressurizing'.Continue with the procedure on the Examiner. Proceed with removal 3238429-5530B10battery - r+r . Proceed with removal 3238435-5530B52Battery DRIP TRAY/SUPPORT- R.R. . Proceed with removal 3237525-1048A10air cleaner filtering element- replace . 1. Disconnect the electrical connection from the electro-hydraulicgear selection position sensor.2. Disconnect the electrical connection from the electro-hydraulicgear selection position sensor.3. Undo the connector and disconnect the pipe between the selectionsolenoid valve and the engagement/selection actuator, gear engagementelectro-hydraulic selection device side. 4. Undo the connector and disconnect the pipe between the even gearengagement solenoid valve and the engagement/selection actuator,gear engagement electro-hydraulic selection device side. 5. Undo the connector and disconnect the pipe between the unevengear engagement solenoid valve and the engagement/selection actuator,gear engagement electro-hydraulic selection device side. 2069823
0Removing201Refitting21Position the vehicle on the rampConnect the Examiner diagnostic equipment.Select 'Alf 156 Selespeed' on the Examiner.Select 'Control Unit Test' on the Examinerand select the 'Marelli Selespeed Automatic Transmission'.Press 'Active Diagnosis' on the Examinerand select 'Accumulator depressurizing'.Continue with the procedure on the Examiner.Ensure that the ignition key is in theOFF position, then disconnect the negative battery terminal (-). Proceed with removal 3238966-7055B54under-engine guard -r r . 1. Disconnect the electrical connection of the gear selection solenoid.2. Undo the bolts (2a) and gear selection solenoid valve (2b).2069829
2127C56
0Removing201Refitting21Connect the Examiner diagnostic equipment.Select 'Alf 156 Selespeed' on the Examiner.Select 'Control Unit Test' on the Examinerand select the 'Marelli Selespeed Automatic Transmission'.Press 'Active Diagnosis' on the Examinerand select 'Accumulator depressurizing'.Continue with the procedure on the Examiner. Proceed with removal 3238429-5530B10battery - r+r . Proceed with removal 3238435-5530B52Battery DRIP TRAY/SUPPORT- R.R. . Proceed with removal 3237525-1048A10air cleaner filtering element- replace . 1. Disconnect the electrical connection from the clutch controlsolenoid.2. Undo the bolts (2a) and remove the clutch control solenoid valve (2b).2069830
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking “Accept All”, you consent to the use of ALL the cookies. However, you may visit "Cookie Settings" to provide a controlled consent.
This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.