AIR CONDITIONING Automatic A/C Wiring Diagram (1 of 2) for Saab 9-5 I рестайлинг поколение 2001–2005 Открыть Войдите — вход по коду из письма займёт минуту (2.3l: on left side of cylinder head) (3.0l: on intake manifold flange) (behind headlamp) g31 (left grounding screw on knee member in cabin) g41p A red A/c compressor A/c compressor relay (on underhood fuse/relay block) A/c evaporator temperature sensor (on passenger's side of heating & ventilation unit) A/c pressure sensor (on bottom right side of condenser) Показать все 78 Свернуть Acc control module (in center of dash) Air distribution damper motor (above passenger's side floor duct outlet) Blend air flap motor (left) (on left end of heating & ventilation unit) Blend air flap motor (right) (on right end of heating & ventilation unit) C15-2 C30-2 C31-16 C35 C36 C37 C38 C39 C59-1 C60-1 C63 C64 C65 C66 C67 C70 C72 C73 C74 C75 C76 C81 C82 C83 C84 C85 C86 C87 C88 C89 C90 C91 C92 C93 C94 C95 Cabin air temperature sensor (in front roof console) Computer data lines system Coolant temperature sensor Dice control module (above interior relay block) E18 E31-10 E35 E69 E70 E71 Fuse 10a Fuse 15a Fuse 30a Fuse 7.5a G41p (left grounding screw on knee member (in cabin)) H2-2 Hot at all times Hot in on Hot in on or start Hot w/main relay (engine mgmt) energized Interior fuse block (behind left end of dash) Nca Recirculation flap motor (behind right side of dash, next to ventilation fan motor) Red Solar sensor (on top center of dash) Solid state Trionic control module (obd ii) (in right rear of engine compartment) Underhood fuse/relay block (at left rear corner of engine compartment) Ventilation fan control unit (on driver's side of heating & ventilation unit, near firewall) Ventilation fan motor (in top of heating & ventilation unit)
Automatic A/C Wiring Diagram (2 of 2) for Saab 9-5 I рестайлинг поколение 2001–2005 Открыть Войдите — вход по коду из письма займёт минуту (engine bay on side panel in front of left wheel housing) g30 Blended air temperature sensor (left) (on left side of heating & ventilation unit, in floor duct outlet) Blended air temperature sensor (right) (on right side of heating & ventilation unit, in floor duct outlet) Coolant circulation pump motor (3.0l) (between cylinder head & shutoff valve) Fuse 1 (maxi) 40a Fuse 30a Heat exchanger solenoid valve (on front edge of heater housing assembly) Hot at all times Показать все 15 Свернуть Left high speed radiator fan relay Left radiator fan motor Low speed 2 radiator fans relay Red Right high speed radiator fan relay Right radiator fan motor Underhood fuse/relay block (at left rear corner of engine compartment)
Другие системы Saab 9-5 I рестайлинг поколение · 2001–2005