Volkswagen Golf Mk7 2012–2017
| Fitting location: |
| In centre of dash panel. |

Полная схема
ОткрытьВойдите — вход по коду из письма займёт минуту
| 1 - | Air conditioning system control unit -J301- / heater control unit -J65- |
| A - | 16-pin connector -T16a- |
| B - | 20-pin connector -T20b- |
|
| -T16a- (A) | Designation | -T20b- (B) | Designation | |||
| 1 | Potentiometer for air distribution flap control motor -G645- , 5V, potentiometer for temperature flap control motor -G92- , 5V | 1 | ||||
| 2 | 2 | |||||
| 3 | 3 | |||||
| 4 | 4 | |||||
| 5 | Temperature flap control motor -V68- | 5 | Convenience CAN bus high | |||
| 6 | Temperature flap control motor -V68- | 6 | Convenience CAN bus low | |||
| 7 | Air distribution flap control motor -V428- | 7 | ||||
| 8 | Air distribution flap control motor -V428- | 8 | ||||
| 9 | Air recirculation flap control motor -V113- | 9 | ||||
| 10 | Air recirculation flap control motor -V113- | 10 | ||||
| 11 | Evaporator temperature sensor -G308-
| 11 | ||||
| 12 | 12 | |||||
| 13 | 13 | |||||
| 14 | Potentiometer for air distribution flap control motor -G645- , Potentiometer for temperature flap control motor -G92- | 14 | ||||
| 15 | 15 | |||||
| 16 | 16 | LIN bus | ||||
| 17 | ||||||
| 18 | Air conditioner compressor regulating valve -N280-
| |||||
| 19 | Terminal 31 | |||||
| 20 | Terminal 30 |
|