| -T46b- (A) | Designation | | -T46b- (A) | Designation | | -T46b- (A) | Designation |
| 1 | Terminal 30, from fuse carrier 2 -ST2- in fuse holder F -SF- | | 17 | | | 33 | Pump for reducing agent -V437- in reducing agent metering system control unit -GX19- |
| 2 | Heater 2 for reducing-agent tank (heater circuit 3) -Z167- in reducing agent metering system control unit -GX19- | | 18 | | | 34 | |
| 3 | Heater for reducing-agent tank (heater circuit 1) -Z102- in reducing agent metering system control unit -GX19- | | 19 | | | 35 | Pump for reducing agent -V437- in reducing agent metering system control unit -GX19- |
| 4 | | | 20 | | | 36 | |
| 5 | | | 21 | | | 37 | Temperature sender for reducing agent -G685- in reducing agent metering system control unit -GX19- |
| 6 | Temperature sender for reducing agent -G685- in reducing agent metering system control unit -GX19- | | 22 | | | 38 | Reducing agent quality sensor -G849- in reducing agent metering system control unit -GX19- |
| 7 | Pressure sender for reducing agent metering system -G686- in reducing agent metering system control unit -GX19- | | 23 | | | 39 | Heater for reducing-agent line (heater circuit 2) -Z104- |
| 8 | Heater for reducing-agent line (heater circuit 2) -Z104- | | 24 | | | 40 | Pressure sender for reducing agent metering system -G686- in reducing agent metering system control unit -GX19- |
| 9 | Pressure sender for reducing agent metering system -G686- in reducing agent metering system control unit -GX19- | | 25 | | | 41 | Tank sender for reducing agent -G684- in reducing agent metering system control unit -GX19- |
| 10 | Reducing agent quality sensor -G849- in reducing agent metering system control unit -GX19- | | 26 | | | 42 | |
| 11 | | | 27 | | | 43 | |
| 12 | Heater 2 for reducing-agent tank (heater circuit 3) -Z167- in reducing agent metering system control unit -GX19- | | 28 | | | 44 | Extended high CAN bus, from B670 connection 3 (extended high CAN bus) in main wiring harness Data bus diagnostic interface -J533- |
| 13 | Heater for reducing-agent tank (heater circuit 1) -Z102- in reducing agent metering system control unit -GX19- | | 29 | | | 45 | Extended CAN bus, low, from B671 connection 3 (extended CAN bus, low) in main wiring harness Data bus diagnostic interface -J533- |
| 14 | Terminal 31, to 400 earth connection 35 in main wiring harness 675 Earth point 2 on right in luggage compartment | | 30 | Terminal 30, from fuse carrier 2 -ST2- in fuse holder F -SF- | | 46 | Terminal 31, to 400 earth connection 35 in main wiring harness 675 Earth point 2 on right in luggage compartment |
| 15 | | | 31 | Pump for reducing agent -V437- in reducing agent metering system control unit -GX19- | | | |
| 16 | | | 32 | Tank sender for reducing agent -G684- in reducing agent metering system control unit -GX19- | | | |